Drayton Mid Position Control Pack - PBBE58


Currently unavailable


Currently unavailable
This Drayton Mid Position Control Pack (PBBE58) is designed for homeowners seeking a comprehensive solution to manage their central heating and hot water systems efficiently. It offers a 'set it and forget it' approach to energy management, ensuring optimal comfort without constant adjustments. A potential consideration is its suitability specifically for biflo systems, requiring confirmation of system type before purchase.
| Model Part Number | PBBE58 |
|---|---|
| Brand | Drayton |
This pack is specifically designed for biflo (two-pipe) central heating systems. It is important to confirm your system type before installation.
Yes, for safety and optimal performance, this control pack should be installed by a qualified heating engineer.
The LP822 universal programmer allows you to set daily and weekly schedules for both heating and hot water. Consult the programmer's manual for detailed instructions on setting times and temperatures.
The 3-port mid-position motorised valve controls the flow of water in your heating system, directing it either to the radiators, to the hot water cylinder, or both, depending on your settings.
Yes, the programmer allows for independent scheduling of heating and hot water, enabling you to set different times and durations for each.
The components require minimal cleaning. A light dusting with a dry cloth periodically is sufficient. Avoid using harsh chemicals or solvents.
Check that the programmer is switched on and set to the correct time and mode (Auto/On). Verify that the thermostats are set to the desired temperatures and that the programmer has called for heat/hot water. Ensure the main power supply to the system is active.
Check the wiring connections to the valve and the programmer. Ensure the programmer is sending the correct signals. Listen for any humming noise from the valve motor; if silent, it may require replacement.
Ensure the room thermostat is correctly positioned away from draughts or direct heat sources. Check the thermostat's temperature setting and verify that the heating system is calling for heat via the programmer and valve.
Adjust the setpoint on the HTS3 cylinder thermostat. Ensure the thermostat probe is correctly inserted into the cylinder's pocket.
Setup: This control pack is designed for installation by a qualified heating engineer. It requires connection to your existing central heating system, including pipework, wiring for the boiler, and power supply. The programmer, thermostats, and motorised valve need to be correctly wired together via the LWC3 junction box according to the manufacturer's wiring diagrams.
Compatibility: This pack is specifically designed for biflo (two-pipe) central heating systems. It is crucial to confirm your system type before installation. It is compatible with most common boilers and standard electrical installations.
Care: The components require minimal user care.