Harting Han K 4/0 Male Connector Insert - 09380062611

This professional-grade male connector insert features 4 contacts with a reliable screw terminatio...

Currently unavailable

Currently out of stock

This product is not available at the moment. Check back later or explore other options below.

Similar alternatives

Product Information

Full details

The Harting Han K 4/0 Male Connector Insert (09380062611) is a professional-grade component engineered for heavy-duty industrial environments where high current and voltage reliability are non-negotiable. Ideal for engineers and maintenance technicians working with power distribution systems, this insert offers robust screw termination for secure connections; however, its specialized size 16 B form factor means it is not compatible with smaller, standard-duty connector housings.

All features

Model Part Number09380062611
BrandHarting

Extended Product Information

FAQs

What is the maximum wire gauge this insert accepts?

It supports conductors ranging from 1.5 mm² up to 16 mm².

Can this be used in freezing temperatures?

Yes, it is rated for operation down to -40°C.

Does this insert come with a housing?

No, this is an insert only; a compatible size 16 B housing must be purchased separately.

How many mating cycles can I expect?

The connector is rated for at least 500 mechanical mating cycles.

Is the material flame retardant?

Yes, it is constructed to meet UL94 V0 flammability standards.

Troubleshooting

Connection overheating

Check that all screw terminals are properly torqued and that the wire cross-section is within the 1.5-16 mm² range.

Difficult insertion into housing

Verify that the insert is correctly oriented and that the housing is a size 16 B variant; do not force the component.

Intermittent electrical continuity

Inspect contact pins for debris or damage from previous cycles; replace the insert if pins show signs of deformation.

Pros and Cons

Pros

  • High current handling up to 80A
  • Extremely durable industrial-grade build
  • Versatile conductor support (1.5 to 16 mm²)
  • Wide operating temperature range
  • Reliable mechanical screw termination

Cons

  • Requires specific size 16 B compatible housing
  • Requires manual screw termination tool
  • Limited to high-power, low-pin-count applications

Setup, Compatibility & Care

To ensure proper function, first verify that your protective housing matches the size 16 B form factor. When terminating wires, strip the insulation to the manufacturer-specified length to prevent exposed copper. Ensure all four screw terminals are tightened to the recommended torque to prevent heating during high-current operation. Regularly inspect the contacts for signs of oxidation or debris if the connector is frequently uncoupled. If the unit is used in harsh, dusty, or moisture-prone environments, ensure the selected housing provides the necessary ingress protection (IP rating) to safeguard the insert.