Eaton Easy Battery+ - EB010SP

The Eaton Easy Battery+ product J is designed to provide reliable performance and exceptional dura...

Currently unavailable

Currently out of stock

This product is not available at the moment. Check back later or explore other options below.

Product Information

Full details

This guide is for users needing a reliable battery replacement for their Eaton 5P UPS system. The Eaton Easy Battery+ EB010SP offers dependable power with its Sealed Lead Acid (VRLA) technology and 9 Ah capacity, ensuring your equipment stays protected during outages. A key consideration is that this is a replacement kit and requires proper installation.

All features

Model Part NumberEB010SP
BrandEaton

Extended Product Information

FAQs

What type of battery technology does the EB010SP use?

The Eaton Easy Battery+ EB010SP uses Sealed Lead Acid (VRLA) battery technology.

How many batteries are included in the EB010SP kit?

The kit includes two 6V batteries.

What is the capacity of each battery?

Each battery has a capacity of 9 Ah.

Can I use these batteries in a UPS that requires 6V?

No, these two 6V batteries are designed to be connected in series to provide a total of 12V for compatible UPS systems. They are not intended for use as single 6V units unless specified by the UPS manufacturer for a different configuration.

What are the physical dimensions of the EB010SP batteries?

Each battery measures approximately 170 mm (Depth) x 210 mm (Width) x 37 mm (Height).

How long should I charge the new batteries before use?

It is recommended to fully charge the new batteries for at least 24 hours after installation before relying on them for backup power.

Troubleshooting

UPS not recognizing new batteries

Ensure batteries are connected in series with correct polarity (+ to -, - to +). Verify that the battery voltage and capacity match the UPS requirements. Check for loose connections.

Short battery runtime

Allow batteries to charge fully for at least 24 hours. Ensure the batteries are not nearing the end of their lifespan. Check UPS load to ensure it does not exceed capacity.

Battery error indicator on UPS

Consult the UPS manual for specific error code meanings. It may indicate a faulty battery or connection issue. If persistent, contact Eaton support.

Pros and Cons

Pros

  • Reliable Sealed Lead Acid (VRLA) technology for consistent performance.
  • Designed as a direct replacement for specific Eaton UPS models, ensuring compatibility.
  • Offers a sufficient 9 Ah capacity for essential power backup.
  • Comes with two 6V batteries, providing the necessary components for a 12V setup.
  • Durable build quality suitable for extended use.

Cons

  • Requires manual installation, which may involve technical expertise.
  • Specific voltage (6V) and capacity (9Ah) limit its use to compatible UPS models.
  • Weight of 2.5 kg needs to be accounted for during installation.
  • Not a user-replaceable part for those seeking 'hot-swap' functionality without proper training.

Setup, Compatibility & Care

Compatibility:

This battery replacement kit is specifically designed for the Eaton 5P UPS series requiring a 12V, 2 x 6V / 9Ah battery configuration. Always verify your UPS model's battery specifications before purchase to ensure compatibility. The Eaton MPN for this product is EB010SP.

Setup:

  1. Safety First: Disconnect the UPS from the mains power and any connected equipment. Ensure you are properly grounded.
  2. Access Batteries: Open the UPS battery compartment according to the UPS manufacturer's instructions.
  3. Remove Old Batteries: Carefully disconnect and remove the old batteries. Note their orientation and terminal connections.
  4. Install New Batteries: Connect the two 6V batteries in series to achieve the required 12V. Ensure correct polarity (+ and - terminals).
  5. Secure Batteries: Place the new batteries securely within the compartment.
  6. Reassemble: Close the UPS battery compartment.
  7. Initial Charge: Reconnect the UPS to the mains power. Allow the new batteries to charge fully before relying on them for backup (typically 24 hours).

Care:

  • Environment: Operate the UPS and batteries within the recommended temperature range to maximize lifespan. Avoid extreme heat or cold.
  • Maintenance: VRLA batteries are sealed and maintenance-free. However, periodically inspect the battery terminals for corrosion and ensure the UPS vents are clear of obstructions.
  • Testing: Regularly test your UPS system under load to ensure the batteries are functioning correctly.