CyberPower Extended Battery Module - BP48VP2U02

The CyberPower BP48VP2U02 Extended Battery Module is designed to significantly increase runtime fo...

Currently unavailable

Currently out of stock

This product is not available at the moment. Check back later or explore other options below.

Product Information

Full details

The CyberPower BP48VP2U02 Extended Battery Module is designed for IT professionals and data center managers who need to significantly increase the runtime of their mission-critical UPS systems during power outages. It provides reliable, extended backup power via a robust 8-cell sealed lead-acid configuration; however, users should note that the unit weighs 30 kg and requires dedicated rack or tower space for proper installation.

All features

Model Part NumberBP48VP2U02
BrandCyberPower

Extended Product Information

FAQs

Can I replace the batteries while the UPS is running?

Yes, the BP48VP2U02 supports hot-swapping, allowing you to replace battery modules without shutting down the connected load.

How long does it take to fully recharge the batteries?

The internal fast charger typically restores the battery to capacity in approximately 6 hours.

Can I use this with any brand of UPS?

No, this module is specifically engineered for use with CyberPower PR1500ERTXL2U, PR2200ERTXL2U, and PR3000ERTXL2U models.

Is the unit heavy?

The module weighs 30 kg (approx. 66 lbs), so ensure your rack mounting hardware is rated for this weight.

What type of batteries are used?

It uses 8 Sealed Lead Acid (VRLA) batteries, each rated at 12V and 9Ah.

What is the expected operating temperature range?

The unit operates optimally within a temperature range of 0 °C to 40 °C.

Troubleshooting

UPS does not recognize the new battery module

Ensure the DC cable is securely seated in the connector and that the UPS is on the list of compatible models.

Battery recharge time appears slower than expected

Verify that the utility line supplying the UPS is providing stable voltage and check that no other high-load devices are interfering with the power input.

Unit exhibits a 'Battery Error' indicator

Perform a self-test through the connected UPS management interface; if the error persists, check for any loose internal battery connections during the next scheduled maintenance.

Pros and Cons

Pros

  • Supports hot-swapping for zero-downtime maintenance
  • Fast-charge technology reduces recovery time after outages
  • Versatile mounting options for rack or tower setups
  • Rugged metal construction for long-term reliability
  • Includes battery equalization for improved battery longevity

Cons

  • Heavy unit (30 kg) requiring secure installation support
  • Limited to specific CyberPower UPS model compatibility
  • Takes up 2U of rack space

Setup, Compatibility & Care

Compatibility

This module is strictly compatible with the following CyberPower UPS systems:

  • PR1500ERTXL2U
  • PR2200ERTXL2U
  • PR3000ERTXL2U

Installation

  1. Ensure the UPS is powered off or in a state that supports EBM (Extended Battery Module) connection.
  2. Use the provided mounting brackets to secure the unit in a rack or stand it upright as a tower.
  3. Connect the DC power cable from the EBM to the compatible port on the back of your UPS.

Care Instructions

  • Temperature: Keep the installation area between 0 °C and 40 °C for optimal battery chemistry performance.
  • Ventilation: Ensure at least 50mm of clearance around the ventilation ports to prevent overheating during the fast-charge process.
  • Humidity: Operate only in environments with non-condensing humidity levels up to 95%.