Phoenix Contact Test Disconnect Terminal Block - 3026272

Professional test disconnect terminal block designed for measurement transformer applications. Fea...

Currently unavailable

Currently out of stock

This product is not available at the moment. Check back later or explore other options below.

Similar alternatives

Product Information

Full details

The Phoenix Contact URTK 6 terminal block is designed for professionals working with measurement transformers, offering a reliable screw connection for electrical circuits. Its key benefit is secure and efficient disconnection for testing purposes. A potential caveat is its specific application focus, requiring users to ensure compatibility with their measurement transformer setups. This terminal block features a single-level screw termination, a robust 500V nominal voltage rating, and a 41A nominal current capacity, supporting wire cross-sections from 0.5mm² to 10mm².

All features

Model Part Number3026272
BrandPhoenix Contact

Extended Product Information

FAQs

What is the primary application for the URTK 6 terminal block?

The URTK 6 terminal block is primarily designed for measurement transformer applications, offering a test disconnect function.

What is the maximum wire size this terminal block can accommodate?

It can accommodate wire cross-sections from 0.5mm² to 10mm².

What mounting rails are compatible with the URTK 6?

It is compatible with NS 35/7.5, NS 35/15, and NS 32 mounting rails.

What is the voltage and current rating?

The nominal voltage rating is 500V, and the nominal current capacity is 41A.

Does this terminal block have a fuse holder?

The URTK 6 is a test disconnect terminal block and does not typically include a fuse holder as a standard feature. Specific variants may exist.

What is the maximum operating temperature?

The maximum operating temperature for this terminal block is +130°C.

How do I perform a test disconnect with this block?

The method for test disconnection depends on the specific variant of the URTK 6. Typically, it involves turning a switch or removing a plug to break the circuit safely.

Troubleshooting

Connection appears loose

Ensure the wire is properly stripped and inserted fully into the terminal. Retighten the screw connection with appropriate torque. Verify the wire gauge is within the specified range.

Terminal block not seating correctly on mounting rail

Confirm that you are using a compatible mounting rail (NS 35/7.5, NS 35/15, or NS 32). Check the rail for any damage or obstructions.

Overheating at connection point

Check if the current exceeds the rated 41A. Ensure the screw connection is tight. Verify the wire gauge is appropriate for the current being carried and the terminal block's specifications.

Pros and Cons

Pros

  • Secure disconnection for testing purposes in measurement transformer circuits.
  • Robust construction suitable for industrial environments.
  • Wide range of wire gauge compatibility.
  • Easy integration with standard mounting rails.
  • High voltage and current ratings ensure broad applicability.

Cons

  • Primarily designed for measurement transformer applications, may not be suitable for general-purpose wiring.
  • Screw connection requires proper torque for optimal performance.
  • Single-level termination limits complex wiring configurations compared to multi-level blocks.

Setup, Compatibility & Care

Setup:

  1. Ensure the terminal block is installed on a compatible mounting rail (NS 35/7.5, NS 35/15, or NS 32).
  2. Strip the wire ends according to the required cross-section (0.5mm² to 10mm²).
  3. Insert the wire into the terminal opening.
  4. Tighten the screw firmly using an appropriate screwdriver to secure the connection. Do not overtighten.

Compatibility:

  • Mounting Rails: NS 35/7.5, NS 35/15, NS 32
  • Wire Cross-Sections: 0.5mm² to 10mm² (AWG 20 - 10)
  • Voltage Rating: Up to 500V
  • Current Rating: Up to 41A

Care:

  • Keep the terminal block clean and free from dust or debris.
  • Periodically check screw connections for tightness, especially in environments with vibration.
  • Avoid exposure to corrosive substances or excessive moisture.