Hager KN22E Terminal - Main Cable - Grounding Rail




Currently unavailable




Currently unavailable
The Hager KN22E Terminal Block is designed for electricians and DIY enthusiasts requiring reliable and space-saving electrical connections for indoor installations. Its key benefit lies in tool-free solid wire insertion for up to 4 mm² conductors and clear color coding for easy identification, ensuring faster and more secure installations. A caveat to note is its suitability strictly for indoor environments. This terminal block features a robust design with a 63 A rated current, screw/spring-loaded connections, and a compact form factor.
| Model Part Number | KN22E |
|---|---|
| Brand | HAGER |
The KN22E is designed for tool-free insertion of *solid* wires up to 4 mm². For stranded wires, you may need to use ferrules or a different connection method, depending on the specific requirements of your installation and local electrical codes.
The Hager KN22E terminal block has a rated current of 63 A, making it suitable for significant electrical loads.
No, the KN22E is designed strictly for indoor use. Exposure to outdoor elements like moisture or extreme temperatures can compromise its performance and safety.
For solid wires up to 4 mm², strip the insulation and push the wire directly into the appropriate port until it is securely held by the internal spring mechanism. Ensure the connection is firm.
The grey and yellow colors are for easy identification. Typically, grey is used for line or neutral conductors, and yellow is used for grounding conductors, helping to prevent wiring errors.
The dimensions are approximately 33 mm in height and 90 mm in width, designed for compact installations.
For inserting solid wires up to 4 mm², no special tools are required beyond wire strippers. If screw terminals are used for specific connections, a screwdriver would be necessary.
Ensure a solid wire (not stranded) is used and inserted fully until it clicks or is firmly seated. Check if the wire gauge is within the 4 mm² limit. If using a screw terminal, ensure it is adequately tightened.
Verify that the terminal block is properly mounted within its intended enclosure or on a DIN rail. Ensure all securing screws or clips are fastened correctly.
Immediately disconnect power and inspect the connection. Ensure the wire gauge is appropriate for the 63 A rating and that all connections are tight. Check for any signs of damage or corrosion. Overloading the circuit can also cause overheating.
Setup:
Compatibility:
Care: