SKINTOP INOX Cable Gland - M12 - Stainless Steel

Corrosion-resistant stainless steel cable gland designed for maritime and food industry applicatio...

Currently unavailable

Currently out of stock

This product is not available at the moment. Check back later or explore other options below.

Similar alternatives

Product Information

Full details

The LAPP SKINTOP INOX Cable Gland (MPN: 53806739) is designed for professionals in the maritime and food industries who require robust, corrosion-resistant cable entry solutions. Its key benefit is superior seawater resistance and smooth surfaces, making it ideal for harsh environments like offshore installations and food processing plants. A key consideration is that locknuts are sold separately. This gland offers a variable clamping range and meets IP68 protection standards, ensuring reliable performance and strain relief.

All features

Model Part Number53806739
BrandLAPP

Extended Product Information

FAQs

What is the primary advantage of using Stainless steel 316 (V4A)?

Stainless steel 316 (V4A) offers superior resistance to corrosion, especially in environments with chlorides like seawater, making it ideal for maritime and food processing applications.

Do I need to purchase a locknut separately?

Yes, locknuts are not included with this cable gland and must be ordered separately.

What is the degree of protection (IP rating) of this gland?

The SKINTOP INOX cable gland has an IP68 rating, indicating it is protected against dust ingress and prolonged immersion in water under specified conditions.

Can this gland be used for outdoor applications?

Yes, its corrosion resistance and IP68 rating make it suitable for many outdoor applications, especially in coastal or wash-down environments.

What is the temperature range for this cable gland?

The operating temperature range for this gland is from -40°C to 100°C.

Is this cable gland suitable for use in food production areas?

Yes, its smooth surfaces and corrosion-resistant material are designed for use in spray zones within food production facilities.

What is the thread type and size?

The thread type is Metric, with a nominal thread size of M12.

Troubleshooting

Gland does not seal properly, allowing moisture ingress.

Verify the cable diameter is within the 4-7mm clamping range. Ensure the sealing ring is properly seated and free of debris. Tighten the cap nut securely.

Difficulty threading the gland into the enclosure.

Confirm you are using a standard M12 threaded enclosure opening. Check for any damage or debris in the enclosure's threads.

Cable slides within the gland despite tightening.

Ensure the cable jacket is clean and smooth. Tighten the cap nut further, ensuring it does not exceed torque limits that could damage the cable. The cable diameter should be appropriate for the gland's clamping range.

Corrosion observed on the gland surface.

While designed for corrosion resistance, extreme conditions may require additional protective measures or more frequent inspection. Ensure the material is indeed Stainless steel 316 (V4A) as specified. Clean affected areas gently.

Pros and Cons

Pros

  • Excellent corrosion resistance due to Stainless steel 316 (V4A) construction.
  • High ingress protection (IP68) for demanding environments.
  • Hygienic design with smooth surfaces suitable for food and beverage industries.
  • Versatile clamping range accommodates multiple cable diameters.
  • Reliable strain relief protects cable integrity.

Cons

  • Locknuts are not included and must be purchased separately.
  • Not suitable for armored cables.
  • Does not feature EMC shielding or screening.
  • Operating temperature range has limitations (-40°C to 100°C).
  • No bend radius protection or trumpet flare.

Setup, Compatibility & Care

Setup:

  1. Select the appropriate mounting hole in your enclosure with an M12 thread.
  2. If using a locknut, ensure it is ordered separately and suitable for the enclosure material.
  3. Prepare the cable by stripping the outer jacket to the appropriate length for insertion into the gland.
  4. Insert the cable through the gland body, ensuring the sealing ring is correctly positioned.
  5. Tighten the cap nut of the gland onto the cable to secure it and create a seal. Ensure the clamping range (4-7mm) is suitable for your cable diameter.
  6. Mount the gland into the enclosure's threaded opening. If using a separate locknut, tighten it on the inside of the enclosure to secure the gland.

Compatibility:

  • Thread Size: M12 (Nominal thread size metric=12)
  • Cable Diameter: 4mm to 7mm
  • Enclosure: Requires a M12 threaded entry.
  • Locknut: Not included, requires separate purchase.

Care:

  • Clean the gland surfaces with a damp cloth. Avoid abrasive cleaners that could damage the stainless steel finish.
  • Periodically inspect for any signs of damage or wear, particularly in harsh environments.
  • Ensure the seal remains intact and free from debris to maintain IP68 rating.