Phoenix Contact UK 5-MTK Knife Disconnect Terminal Block - 3004430

Professional screw-connection knife disconnect terminal block rated at 500V/16A. Features a single...

Currently unavailable

Currently out of stock

This product is not available at the moment. Check back later or explore other options below.

Similar alternatives

Product Information

Full details

This Phoenix Contact UK 5-MTK terminal block is designed for electrical engineers and panel builders working with industrial control systems. Its primary benefit is providing a secure, single-level screw connection for wiring up to 2.5 mm² or 10 AWG, with a disconnect function for safe maintenance. A potential caveat is its specific voltage and current rating, which must be matched to the application's requirements.

All features

Model Part Number3004430
BrandPhoenix Contact

Extended Product Information

FAQs

What is the maximum wire size this terminal block can accommodate?

The UK 5-MTK terminal block can accommodate wire sizes from 0.2 mm² up to 6 mm², which corresponds to American Wire Gauge (AWG) sizes from 24 to 10.

What is the purpose of the knife disconnect feature?

The knife disconnect allows for safe electrical isolation of the connected circuit. This is crucial for maintenance, testing, or troubleshooting, as it enables a specific circuit to be safely de-energized without disconnecting individual wires.

What types of DIN rail can this terminal block be mounted on?

This terminal block is compatible with standard DIN rail profiles: NS 35/7.5, NS 35/15, and NS 32.

What is the voltage and current rating of this terminal block?

The Phoenix Contact UK 5-MTK terminal block is rated for a maximum voltage of 500V and a maximum current of 16A.

What color is the housing of this terminal block?

The housing of the UK 5-MTK terminal block is gray.

Is this terminal block suitable for outdoor use?

While constructed for industrial environments, specific environmental protection (like IP ratings) is not detailed. It is best suited for use within control panels or enclosures, protected from direct exposure to weather, moisture, and extreme temperatures.

How do I install a wire into the terminal block?

Strip the wire end to the appropriate length, insert it into the terminal opening, and then tighten the screw with a screwdriver to secure the connection.

Troubleshooting

Connection is loose or intermittent.

Ensure the wire is stripped to the correct length and fully inserted into the terminal. Tighten the screw securely without overtightening. Check for any debris or corrosion on the wire or terminal contacts.

Terminal block does not sit securely on the DIN rail.

Verify that the correct type of DIN rail (NS 35/7.5, NS 35/15, or NS 32) is being used and that it is installed correctly. Ensure the terminal block's mounting clip is fully engaged.

Disconnect knife is stiff or difficult to operate.

Ensure no wires are obstructing the knife mechanism. Check for any foreign debris in the disconnect slot. If stiffness persists, consult the manufacturer's documentation or support.

Overheating at the terminal connection.

Immediately disconnect power. Check that the wire gauge is within the specified range (0.2-6 mm² / AWG 24-10) and that the screw is adequately tightened. Ensure the circuit's current draw does not exceed the 16A rating.

Pros and Cons

Pros

  • Secure and reliable screw terminal connections.
  • Integrated disconnect function enhances safety during maintenance.
  • Space-saving single-level design.
  • Broad compatibility with common DIN rail types.
  • Suitable for a wide range of industrial wiring needs with its voltage and current ratings.

Cons

  • Limited to 500V and 16A, not suitable for high-power applications.
  • Requires manual wire stripping and insertion.
  • Gray color may not match all panel aesthetics.
  • Single-level design might limit connection density compared to multi-level blocks.

Setup, Compatibility & Care

Setup:

  1. Ensure the terminal block is properly seated on a compatible DIN rail (NS 35/7.5, NS 35/15, or NS 32).
  2. Strip the conductor ends to the appropriate length, typically corresponding to the terminal's internal depth.
  3. Insert the stripped conductor into the screw terminal opening.
  4. Tighten the screw firmly using a suitable screwdriver to secure the connection. Do not overtighten.
  5. For the disconnect function, the knife blade can be actuated with a screwdriver or appropriate tool.

Compatibility:

  • DIN Rails: NS 35/7.5, NS 35/15, NS 32.
  • Wire Size: 0.2 mm² to 6 mm² (AWG 24 to 10).
  • Voltage/Current: Suitable for circuits rated up to 500V and 16A.

Care:

  • Keep the terminal block clean and free from dust and debris. A dry or slightly damp cloth can be used for cleaning.
  • Periodically check screw connections for tightness, especially in environments with vibration. Ensure power is disconnected before performing checks.
  • Avoid exposing the terminal block to excessive moisture or corrosive substances.